Features And Applications
The pump is widely used in industries such as: petrochemical, grease, food, beverage, medicine and hygiene, power, textile, printing & dyeing, water treatment, environment protection, water supply of buildings and boiler, etc. It is suitable for conveying media with the temperature of less than180'C.
Technical Data
1 .Designed pressure: 1 .OMpa
2.Working temperature:-40t;~180'C;
3.Materials of mechanic seal
Static ring: (ceramic /carborundum/tungsten carbide)
Movable ring (graphite /carborundum / tungsten carbide)
Sealing ring: ( butadieneacrylonitrile rubb-er/ethylene propylene terpolymer/fluoroelastomer /polytetrafluoroethylene)
Description Of Model
Table of Technical data
Model | impellerform | Capacitym3/h | Headm | Apeedrpm | %Efficiency | (kw)motorPower | NPSHr(m) | |
lCB | ICB(D) | |||||||
ICB20-12-125 | O | 1.6 | 20 | 2900 | 47 | 0.37 | 3.5 | |
ICB20-12-160 | O | 1.6 | 30 | 41 | 0.37 | 3.8 | ||
A | 1.2 | 24 | 40 | 0.55 | ||||
ICB32-25-125 | O | 3.2 | 20 | 45 | 0.55 | 3.5 | ||
ICB32-25-160 | O | 32 | 30 | 40 | 0.9 | 3.8 | ||
A | 2.5 | 24 | 39 | 0.75 | ||||
ICB50-25-125 | O | 6.3 | 20 | 61 | 1.5 | 1.5 | 2 | |
A | 5 | 15 | 60 | 1.1 | 1.1 | |||
lCB50-25-160 | O | 6.3 | 32 | 57 | 2.2 | 3 | 2 | |
A | 5 | 25 | 56 | 1.5 | 2.2 | |||
ICB50-25-200 | O | 6.3 | 50 | 49 | 4 | 5.5 | 2 | |
A | 5 | 40 | 48 | 3 | 4 | |||
ICB50-32-125 | O | 12.5 | 20 | 63 | 1.5 | 2.2 | 2 | |
A | 10 | 15 | 62 | 1.1 | 1.5 | |||
ICB50-32-160 | O | 12.5 | 32 | 58 | 2.2 | 3 | 2 | |
A | 10 | 25 | 57 | 1.5 | 2.2 | |||
ICB50-32-200 | O | 12.5 | 50 | 50 | 4 | 5.5 | 2 | |
A | 10 | 40 | 49 | 3 | 4 | |||
ICB65-50-125 | O | 25 | 20 | 72 | 22 | 3 | 2 | |
A | 20 | 15 | 71 | 1.5 | 2.2 | |||
ICB65-50-160 | O | 25 | 32 | 70 | 4 | 5.5 | 2 | |
A | 20 | 25 | 69 | 3 | 4 | |||
ICB65-40-200 | O | 25 | 50 | 64 | 7.5 | 7.5 | 2 | |
A | 20 | 40 | 63 | 5.5 | 7.5 | |||
lCB80-65-125 | O | 50 | 20 | 78 | 4 | 5.5 | 2 | |
A | 40 | 15 | 77 | 3 | 4 | |||
ICB80-65-160 | O | 50 | 32 | 75 | 7.5 | 7.5 | 2 | |
A | 40 | 25 | 74 | 5.5 | 7.5 | |||
ICB80-50-200 | O | 50 | 50 | 73 | 11 | 15 | 2 | |
A | 40 | 40 | 72 | 9 | 11 | |||
ICB100-80-125 | O | 100 | 20 | 76 | 9 | 11 | 2 | |
A | 80 | 15 | 75 | 7.5 | 7.5 |
Model | impellerform | Capacitym3/h | Headm | Apeedrpm | %Efficiency | (kw)motorPower | NPSHr(m) | |
ICB | ICB(D) | |||||||
ICB20-12-125 | O | 3.2 | 5 | 53 | 0.37 | 0.37 | ||
A | 2.5 | 4 | 51 | 0.37 | 0.37 | 1.7 | ||
ICB50-25-160 | O | 3.2 | 8 | 47 | 0.55 | 0.55 | ||
A | 2.5 | 62 | 43 | 0.37 | 0.37 | 1.7 | ||
ICB50-25-200 | O | 3.2 | 12.5 | 41 | 0.75 | 0.75 | ||
A | 2.5 | 10 | 39 | 0.55 | 0.55 | 1.7 | ||
ICB50-32-125 | O | 6.3 | 5 | 55 | 0.55 | 0.55 | ||
A | 5 | 4 | 53 | 0.37 | 0.37 | 1.7 | ||
ICB50-32-160 | O | 6.3 | 8 | 49 | 0.55 | 0.55 | ||
A | 5 | 62 | 45 | 0.55 | 0.55 | 1.7 | ||
ICB50-32-200 | O | 6.3 | 12.5 | 43 | 0.75 | 0.75 | ||
A | 5 | 10 | 41 | 0.55 | 0.55 | 1.7 | ||
ICB65-50-125 | O | 12.5 | 5 | 64 | 0.55 | 0.55 | ||
A | 10 | 4 | 58 | 0.55 | 0.55 | 1.7 | ||
ICB65-50-160 | O | 12.5 | 8 | 62 | 0.75 | 0.75 | ||
A | 10 | 6.2 | 60 | 0.55 | 0.55 | 1.7 | ||
ICB65-40-200 | O | 12.5 | 12.5 | 55 | 1.1 | 1.1 | ||
A | 10 | 10 | 54 | 0.75 | 0.75 | 1.7 | ||
ICB80-65-125 | O | 25 | 5 | 71 | 0.75 | 0.75 | ||
A | 20 | 4 | 67 | 0.55 | 0.55 | 2 | ||
ICB80-65-160 | O | 25 | 8 | 70 | 1.5 | 1.5 | ||
A | 20 | 6.2 | 64 | 1.1 | 1.1 | 2 | ||
ICB80-50-200 | 0 | 25 | 12.5 | 69 | 2.2 | 2.2 | ||
A | 20 | 10 | 62 | 1.5 | 1.5 | 2 | ||
ICB100-80-125 | O | 50 | 5 | 71 | 1.5 | 2.2 | ||
A | 40 | 4 | 68 | 1.1 | 1.5 | 2 |